NET-PwrCtrl HUT 2

  • 8 - independent sockets controlled via Ethernet / Internet using the web browser. Worldwide control.
  • Push or screw terminals.
  • RJ45 socket for sensor.
  • No software (except web browser) necessary to control or adjust.
  • Can be used by any operating system (with a web browser).
  • HTML of the pages can be changed and loaded.
  • Automatic IP allocation: DHCP.
  • Start time (ready for operation) 3 seconds.
  • 8 - inputs or outputs - freely configurable with edge detection and toggle.
  • io

  • Automatic time setting from an SNTP server.
  • zeit

  • Call via hostname = http://net-control or IP.
  • Name/Position/Function with max. 35 characters.
  • Free choice of the HTTP port (0-65535), thus several devices can be accessed from the Internet.
  • 'HoldOn' Button: Relay or IO is activated as long as the key is held down. Two relays or IO's can thus be used for +/- control (e.g., dimmers).
  • 4 timers + 1 random timer +1 solar timer per socket with TimeLine display.
  • Exceptions (day / month). On selected days, all timers are skipped.
  • E-Mail function.
  • Plain text backup system. Settings can be changed and loaded.
  • Keepalive function: A network device can be pinged and - should it not respond - be disconnected
    from the power supply for an adjustable time.
  • ka

  • Automatic and time-delayed (0-18.2h) switching on of the sockets after the start (power failure).
  • Switching can also be performed as pulse (0-65535 sec.).
  • Switching distance of the relays with simultaneous switching can be determined ((0-255) milliseconds).
    sv

  • Wake on LAN
  • wol

  • Sockets can be locked individually.
  • User system with rights.
  • user
  • Logbook of the last 128 events. Power failures are registered (remains without voltage).
  • UDP & URL interface for integration into own software.
  • LabView Virtual Instrument for UDP interface.
  • Multi NET-PwrCtrl Controls all devices on the network (also as C# source code).
  • Firmware upgrade via Ethernet possible at any time (Ethernet Bootloader).
  • Sturdy DIN rail housing with the UL94V0 certificate.
Characteristics: HUT2 - LV (Low Voltage) HUT2 - HV (High Voltage)
  Push contact Screw contact Push contact Screw contact
 
  HUT2-LV HUT2-LV-S HUT2-HV HUT2-HV-S
Relay 8 8
I/O 8 8
Rated voltage 8-30V~/10-40V- 100-240V~ 50-60Hz
Power Consumption 1,6 W 3,0 W
Max. Load
each relay
16A/250V~ (resistive load)
16A/14-
TÜV R50126372
Terminals AK4101 Connection cross sections
Push contact Solid 0,08 mm²-2,5 mm²
  Stranded (flexible) 0,5mm²-1,5 mm²
  Stranded with Ferrule 0,14 mm²-1,0 mm²
Ratings VDE 250V 17,5A
Test Voltage 2,0 kV
Terminals AKZ700 Connection cross sections
Screw contact Solid 0,2 mm² - 4,0 mm²
  Stranded (flexible) 0,2 mm² - 2,5 mm²
  Stranded with Ferrule 0,25 mm² - 2,5 mm²
Ratings VDE 250V 24A
Test Voltage  2,0 kV
LAN - Cable 2 m
LAN-Port 10 Base-T,10 MBit/s
Dimensions L 106,5 B 95 H 63mm
6 Fuses wide
35mm DIN rail
Temperature range -20°C...+60°C
Humidity 10 ... 90% not condensed
Delivery: NET-PwrCtrl HUT, Ethernet-Cable.
Manual as PDF pdf Beschrijving (NL) pdf
Online Shop adv adv adv adv